Design a Central Air Conditioning System Using Variable Air Volume Type for a Hospital in Zuwarah City, Libya
Researcher(s): | - Hatem Moustafa H Bshena
- Abdullah Almahjoub Aribi
- ASSiddiq Mohammed Alhinqary
|
Institution: | Department of Mechanical Engineering, Faculty of Engineering. University of Zawia |
Field: | التقنيات الميكانيكية و المواد الهندسية |
Published in: | 32nd volume - July 2023 |
الملخص
الهدف الرئيسي من هذا المشروع هو تصميم نظام تكييف هواء مركزي لمستشفى يقع في مدينة زوارة -ليبيا، تم في هدا البحث دراسة وتقييم مجموعة مختلف من أنظمة تكييف الهواء ومن بين هده الأنظمة تم دراسة نظام تغيير معدل تدفق الهواء الحجمي بالتفصيل وتم بعد لك اختياره واعتماده كنظام تكيف هواء للمستشفى المستهدف من الدراسة. تم دراسة الخصائص الطبيعية والانشائية للموقع والمبني المراد دراسته ثم تم تحديد درجة التصميم الخارجية بناء على بيانات الأرصاد الجوية للموقع باستخدام برنامج (Autodesk Revit MEP 2015).
تم في هده المرحلة حساب الأحمال الحرارية للمبنى، ثم بعد ذلك تم حساب معدل التدفق الحجمي للهواء والذي تم استخدامه في تصميم مجاري الهواء باعتماد طريقتين وهما (طريقة الاحتكاك المتساوي، وطريقة السرعة المتناقصة)، حيث تم استخدام الطريقة الاولى في حساب حجم مجاري الهواء القصيرة، والثانية استخدمت في حساب حجم مجاري الهواء الطويلة.
كلمات مفتاحية: أنظمة تكييف الهواء، نظام تغيير معدل تدفق الهواء الحجمي، تصميم مجاري الهواء، برنامج Autodesk Revit MEP 2015.
Abstract
The main objective of this paper is to design a central air conditioning system for a hospital located at Zuwarah city, Libya. Different types of air conditioning systems were studied and evaluated. Variable air volume system (VAV) had been studied in details and accordingly was selected for the hospital. The outdoor design condition had been determined according to the metrological data for the proposed site using a program called (Autodesk Revit MEP 2015).The nature, the constructions specifications of the site and the building that need to be conditioned were studied. Then; the thermal loads for the building have been calculated. The air volume flow rate was calculated as well and those calculations were essentials in the process of air duct design and duct sizing. The air duct design was obtained using two different methods (Equal Friction Loss Method, and Velocity Reduction Method). The first method was used to calculate the size of the short air ducts, and the second method was used to calculate the size of the long air ducts.
Keywords: Heating, Ventilating, and Air conditioning (HVAC) System, variable air volume (VAV), Duct Design, Autodesk Revit MEP 2015.